MGT 5 frei 2

MGT 5

Emission Tester for petrol engines (4-/5-gas measuring cells)

VP 135108
Description

  • Low current emissions tester without display (basic unit) for the analysis of HC, CO, CO2, O2 emissions with calculation of Lambda
  • Automatic switch-off (prevents condensed water from penetrating test chamber)
  • Separate pump for separation of condensed water
  • Emission testing of CNG, LPG and Otto engines possible
  • Display of measured values via PC/laptop monitor (option)
  • Options:
    ○ Can be expanded to measure NO
    ○ LED-display module (as additional slave monitor)
  • Automatic self-check

Standard Delivery:

  • Basic gas analyser in strong steel housing and painted in RAL 5010, blue
  • Combined water separator and main filter unit
  • Active carbon filter, calibration gas connection, external O2 sensor, emissions probe made of 400 mm woven steel with holding clamp and sealing plugs, emissions probe (8 m) with pre-filter, hose for condensed water escape, instruction manual, approval certificate
  • USB control module interface cable
  • 3 m USB interface cable
  • Software Terminal-/Basic Program (Profi-/Eurosystem for cars):
    ○ Manual data entry
    ○ Automatic data transmission of external equipment
    ○ Terminal networking with PC-network
    ○ Connection to asanetwork possible
  • Measurement software without country-specific emissions testing procedure
  • Packing included

Documents
FR356000 012-de.pdfDE |
MGT 5
DE | EN | ES |
Technical data
Measurable gasesHC, CO, CO2, O2, NO (Option)
Measuring principle Infrared spectrometryHC, CO, CO2
Measuring principle Electrochemical detectionO2, NO
Warm-up time480 s
Flow3.5 l/min
Working pressure0.75 bar - 1.1 bar
Accuracy classO (OIML)
On-board voltage12 V / 42 V
Power supply1/N/PE 85 V/285 V 50 Hz
Dimensions total (L x W x H)240 mm x 560 mm x 300 mm
Weight10 kg
CO - Measurement range / Measured value resolution (max.) - 15 % Vol. / 0,01
CO2 - Measurement range / Measured value resolution (max.) - 20 % Vol. / 0,01
HC - Measurement range / Measured value resolution (max.) - 9999 ppm / 0,1 (Hexan) 0 - 20000 ppm / 1 (Propan
O2 - Measurement range / Measured value resolution (max.) - 25 % Vol. / 0,01
Lambda (calculated)0,5 - 9,99 / 0,01
NO (Option) - Measurement range / Measured value resolution (max.) - 5000 ppm / 1